EPX | VAL6

Share with a Friend


EPX is the Val6 Series’ Most Powerful, Yet Efficient Model Ever

 

With the enlarged combustion chamber, 20% larger radiation disk, and improved atomization, the coexistence of power and economy is now possible.

 

EPX features a state-of-the-art High/Low output control that enables its user to choose between a high or low output setting, thus making it very economical.

 

With a 15-gallon tank, the EPX is able to operate continuously for 20 hrs with low output setting and 15 hrs with a high output setting. The EPX also has a built-in heater for fuel lines and a built-in thermostat.

 

EPX also boasts an Advanced Monitoring System that includes automatic shutdown. In the event that the main body reaches above normal temperatures or the system detects overvoltage conditions, the heater will automatically shut down to prevent the malfunction of the main components.

 

Safety Features:

  • Prevention of Overheating
  • Tip-over Protection
  • Overvoltage Detection
  • Flame Monitor
  • After Power Outage

 

Specifications:

  • High Heat Output: 140,000 BTU/hr
  • Low Heat Output: 100,000 BTU/hr
  • Fuel Type: Diesel, Kerosene
  • High Fuel Consumption: 1.02 Gal/hr
  • Low Fuel Consumption: 0.75 Gal/hr
  • Tank Capacity: 15.4 Gal
  • Power Source: 120V, 60Hz
  • High Noise Level (in operation): 67dB (A)
  • Low Noise Level (in operation): 63 dB (A)
  • Dry Weight: 110 Lbs.
  • Dimensions (H x W x D): 38.2 x 25.4 x 48.6 inches
  • Daystar
  • KBE5-S
  • K
     KBE5L (2-STEP)
    HEAT OUTPUT (BTU/HR)High: 118,000 Low: 100,000
    NOZZLE (GAL/HR)High: 0.90 Low: 0.75
    FUEL TYPEDiesel, Kerosene
    TANK CAPACITY (GAL)15
    POWER SOURCE120V, 60Hz
    POWER CONSUMPTION IN IGNITION (W)150
    POWER CONSUMPTION IN OPERATION (W)High: 97 Low: 96
    ADJUSTABLE DISK ANGLETilt upward 20 degrees
    DIMENSIONS (IN)36.3H x 28.0W x 29.2D
    WEIGHT (LBLS)92.6
    SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Tip-over switch

     

    BE5-L
  • EPX
  • MPX
  • GP5II/GN5
  • FIR1300
  • Hotgun 125NA
  • Request a Demo

Model Numbers & Product Specs


 DAYSTAR
HEAT OUTPUT (BTU/HR)51,200
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)2.6
POWER SOURCE120V, 60Hz 1PH
POWER CONSUMPTION (W)120
CONTROL SYSTEM (SEC)5 Prepurge 330 Postpurge
BURNER TYPEHigh-pressure spray gun type
DIMENSIONS (IN)23.4H x 12.2W x 22.8D
WEIGHT (LBLS)40
SAFETY FEATURES

Photocell flame monitor, 3A Fuse, Overheat prevention system, Tip-over switch

 

Model Numbers & Product Specs


 KBE5S
HEAT OUTPUT (BTU/HR)111,000
NOZZLE (GAL/HR)0.85
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)9
POWER SOURCE120V, 60Hz
POWER CONSUMPTION (W)100
ADJUSTABLE DISK ANGLETilt upward 20 degrees
DIMENSIONS (IN)36.1H x 25.8W x 27.7D
WEIGHT (LBLS)83.8
SAFETY FEATURES

Photocell flame monitor, 3A Fuse, Tip-over switch

 

Model Numbers & Product Specs


 KBE5L (2-STEP)
HEAT OUTPUT (BTU/HR)High: 118,000 Low: 100,000
NOZZLE (GAL/HR)High: 0.90 Low: 0.75
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)15
POWER SOURCE120V, 60Hz
POWER CONSUMPTION IN IGNITION (W)150
POWER CONSUMPTION IN OPERATION (W)High: 97 Low: 96
ADJUSTABLE DISK ANGLETilt upward 20 degrees
DIMENSIONS (IN)36.3H x 28.0W x 29.2D
WEIGHT (LBLS)92.6
SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Tip-over switch

 

Model Numbers & Product Specs


 EPX
HEAT OUTPUT (BTU/HR)High: 140,000 Low: 100,000
FUEL TYPEDiesel, Kerosene
FUEL CONSUMPTION (GAL/HR)High: 1.02 Low: 0.75
TANK CAPACITY (GAL)15.4
OPERATING TIME (HR)High: 15 Low: 20
POWER SOURCE120V, 60Hz
POWER CONSUMPTION IN IGNITION (W)123
POWER CONSUMPTION IN OPERATION (W)120V, 60Hz
NOISE LEVEL (dB)High: 67 Low: 63
DIMENSIONS (IN)38.2H x 25.4W x 48.6D
WEIGHT (LBLS)110
SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Overheat protection, Tip-over switch, Overvoltage detector

 

Model Numbers & Product Specs


 MPX
HEAT OUTPUT (BTU/HR)High: 62,500 Low: 55,500
FUEL TYPE

Kerosene or Fuel-Oil no heavier than No.2 (Diesel)

TANK CAPACITY (GAL)6.6
FUEL CONSUMPTIONHigh: 13.7 Low: 15.7
POWER SOURCE100V, 60Hz
POWER CONSUMPTION IN IGNITION (W)110
POWER CONSUMPTION IN OPERATION (W)145
AIRFLOW (CFM)110
NOISE LEVEL (dB)High: 59.4 Low: 57.8
ADJUSTABLE DISK ANGLEVertical angle of radiation disk can be adjusted up to 45 degrees
DIMENSIONS (IN)28.4H x 20.5W x 26.6D
WEIGHT (LBLS)70.5
SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Tip-over switch, Electrical system protection, Overheat

 

Model Numbers & Product Specs


 GP5II / GN5
HEAT OUTPUT (BTU/HR)144,000
FUEL TYPEGN5: Natural Gas GP5: Propane Gas
FUEL CONSUMPTION (CFH)GN5: 137 (6.1 LBS/HR) GP5: 55.8 (6.6 LBS/HR)
POWER SOURCE120V, 60Hz
POWER CONSUMPTION IN IGNITION (W)107
POWER CONSUMPTION IN OPERATION (W)93
NOISE LEVEL (dB)60
DIMENSIONS (IN)35.3H x 31.7W x 30.3D
WEIGHT (LBLS)108.1
SAFETY FEATURES

Overheat prevention system, Tip-over switch, Auto-restart prevention Fuse

 

Model Numbers & Product Specs


 FIR1300
HEAT OUTPUT (BTU/HR)52,000
FUEL TYPEKerosene or Fuel-Oil no heavier than no. 2 (Diesel)
FUEL CONSUMPTION (GAL/HR)0.32
TANK CAPACITY (GAL)8
OPERATING TIME (HR)21 - 22
POWER SOURCE120V 60 HZ
POWER CONSUMPTION IN IGNITION (W)70
POWER CONSUMPTION IN OPERATION50
DIMENSIONS (IN)36.2H x 12.6W x 45.3D
SAFETY FEATURES

Flame monitor, Overheat prevention, Over-current shorting, Mortor overheat prevention, Tip-over switch, Motor rotation detection

CARBON MONOXIDE DENSITY (PPM)

0

OPERATING NOISE (dB)

50

 

Model Numbers & Product Specs


 HOTGUN 125NA
HEAT OUTPUT (BTU/HR)116,000
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)14.3
HOT AIR FLOW (CFM)636
POWER SOURCE110 - 120V 50/60 HZ 1PH
FUEL CONSUMPTION (GAL/HR)0.9
POWER CONSUMPTION (W)176
CONTROL SYSTEM (SEC)Prepurge: 5 Postpurge: 180
SAFETY DEVICEPhotocell flame monitor, Fuse, Overheat prevention
BURNER TYPEHigh-pressure spray gun type
WEIGHT (LBS)82

 

Request a Product Demo


Related Products


more from this brand