MPX | VAL6

Share with a Friend


MPX is the Reflection of 35 Years of Technological Advancement

 

Combing two worlds, Infrared and convectional heating systems, the MPX with its compact size can still be used for commercial-grade applications as well as applications requiring limited space. 

 

The heat from the air and radiant energy result in the highest efficiency heater, the MPX.  MPX equips a larger radiation disk and improves combustion efficiency by 13% and is able to provide more heat further away compared to the Daystar.

 

Safety Features:

  • Photocell Flame Monitor
  • 3A Fuse
  • Overheat Protection
  • Tip-over Protection

 

Specifications:

  • High Heat Output: 62,500 BTU/hr
  • Low Heat Output: 55,500 BTU/hr
  • Fuel Type: Diesel, Kerosene
  • High Fuel Consumption: 0.48 Gal/hr
  • Low Fuel Consumption: 0.42 Gal/hr
  • Tank Capacity: 6.6 Gal
  • Power Source: 100V, 60 Hz
  • High Operating Time: 13.7 hrs
  • Low Operating Time: 15.7 hrs
  • High Noise Level: 59.4dB
  • Low Noise Level: 57.8dB
  • Dry Weight: 70.5 Lbs.
  • Dimensions (H x W X D): 28.4 x 20.5 x 26.6 inches

 

  • Daystar
  • KBE5-S
  • KBE5-L
  • EPX
  • MPX
  • GP5II/GN5
  • FIR1300
  • Hotgun 125NA
  • Request a Demo

Model Numbers & Product Specs


 DAYSTAR
HEAT OUTPUT (BTU/HR)51,200
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)2.6
POWER SOURCE120V, 60Hz 1PH
POWER CONSUMPTION (W)120
CONTROL SYSTEM (SEC)5 Prepurge 330 Postpurge
BURNER TYPEHigh-pressure spray gun type
DIMENSIONS (IN)23.4H x 12.2W x 22.8D
WEIGHT (LBLS)40
SAFETY FEATURES

Photocell flame monitor, 3A Fuse, Overheat prevention system, Tip-over switch

 

Model Numbers & Product Specs


 KBE5S
HEAT OUTPUT (BTU/HR)111,000
NOZZLE (GAL/HR)0.85
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)9
POWER SOURCE120V, 60Hz
POWER CONSUMPTION (W)100
ADJUSTABLE DISK ANGLETilt upward 20 degrees
DIMENSIONS (IN)36.1H x 25.8W x 27.7D
WEIGHT (LBLS)83.8
SAFETY FEATURES

Photocell flame monitor, 3A Fuse, Tip-over switch

 

Model Numbers & Product Specs


 KBE5L (2-STEP)
HEAT OUTPUT (BTU/HR)High: 118,000 Low: 100,000
NOZZLE (GAL/HR)High: 0.90 Low: 0.75
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)15
POWER SOURCE120V, 60Hz
POWER CONSUMPTION IN IGNITION (W)150
POWER CONSUMPTION IN OPERATION (W)High: 97 Low: 96
ADJUSTABLE DISK ANGLETilt upward 20 degrees
DIMENSIONS (IN)36.3H x 28.0W x 29.2D
WEIGHT (LBLS)92.6
SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Tip-over switch

 

Model Numbers & Product Specs


 EPX
HEAT OUTPUT (BTU/HR)High: 140,000 Low: 100,000
FUEL TYPEDiesel, Kerosene
FUEL CONSUMPTION (GAL/HR)High: 1.02 Low: 0.75
TANK CAPACITY (GAL)15.4
OPERATING TIME (HR)High: 15 Low: 20
POWER SOURCE120V, 60Hz
POWER CONSUMPTION IN IGNITION (W)123
POWER CONSUMPTION IN OPERATION (W)120V, 60Hz
NOISE LEVEL (dB)High: 67 Low: 63
DIMENSIONS (IN)38.2H x 25.4W x 48.6D
WEIGHT (LBLS)110
SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Overheat protection, Tip-over switch, Overvoltage detector

 

Model Numbers & Product Specs


 MPX
HEAT OUTPUT (BTU/HR)High: 62,500 Low: 55,500
FUEL TYPE

Kerosene or Fuel-Oil no heavier than No.2 (Diesel)

TANK CAPACITY (GAL)6.6
FUEL CONSUMPTIONHigh: 13.7 Low: 15.7
POWER SOURCE100V, 60Hz
POWER CONSUMPTION IN IGNITION (W)110
POWER CONSUMPTION IN OPERATION (W)145
AIRFLOW (CFM)110
NOISE LEVEL (dB)High: 59.4 Low: 57.8
ADJUSTABLE DISK ANGLEVertical angle of radiation disk can be adjusted up to 45 degrees
DIMENSIONS (IN)28.4H x 20.5W x 26.6D
WEIGHT (LBLS)70.5
SAFETY FEATURESPhotocell flame monitor, 3A Fuse, Tip-over switch, Electrical system protection, Overheat

 

Model Numbers & Product Specs


 GP5II / GN5
HEAT OUTPUT (BTU/HR)144,000
FUEL TYPEGN5: Natural Gas GP5: Propane Gas
FUEL CONSUMPTION (CFH)GN5: 137 (6.1 LBS/HR) GP5: 55.8 (6.6 LBS/HR)
POWER SOURCE120V, 60Hz
POWER CONSUMPTION IN IGNITION (W)107
POWER CONSUMPTION IN OPERATION (W)93
NOISE LEVEL (dB)60
DIMENSIONS (IN)35.3H x 31.7W x 30.3D
WEIGHT (LBLS)108.1
SAFETY FEATURES

Overheat prevention system, Tip-over switch, Auto-restart prevention Fuse

 

Model Numbers & Product Specs


 FIR1300
HEAT OUTPUT (BTU/HR)52,000
FUEL TYPEKerosene or Fuel-Oil no heavier than no. 2 (Diesel)
FUEL CONSUMPTION (GAL/HR)0.32
TANK CAPACITY (GAL)8
OPERATING TIME (HR)21 - 22
POWER SOURCE120V 60 HZ
POWER CONSUMPTION IN IGNITION (W)70
POWER CONSUMPTION IN OPERATION50
DIMENSIONS (IN)36.2H x 12.6W x 45.3D
SAFETY FEATURES

Flame monitor, Overheat prevention, Over-current shorting, Mortor overheat prevention, Tip-over switch, Motor rotation detection

CARBON MONOXIDE DENSITY (PPM)

0

OPERATING NOISE (dB)

50

 

Model Numbers & Product Specs


 HOTGUN 125NA
HEAT OUTPUT (BTU/HR)116,000
FUEL TYPEDiesel, Kerosene
TANK CAPACITY (GAL)14.3
HOT AIR FLOW (CFM)636
POWER SOURCE110 - 120V 50/60 HZ 1PH
FUEL CONSUMPTION (GAL/HR)0.9
POWER CONSUMPTION (W)176
CONTROL SYSTEM (SEC)Prepurge: 5 Postpurge: 180
SAFETY DEVICEPhotocell flame monitor, Fuse, Overheat prevention
BURNER TYPEHigh-pressure spray gun type
WEIGHT (LBS)82

 

Request a Product Demo